EMAIL US

How to Use the WiFi Boiler Thermostat?

Ⅰ. Start the temperature setting of WiFi boiler thermostat


Plug the WiFi boiler thermostat power cord into the 220V mains power socket. After digital display on the panel, press the “+” key or “-” key to set the starting temperature. The temperature displayed on the gauge outfit is the starting temperature of the circulating pump.


Ⅱ. Stop the temperature setting of WiFi boiler thermostat


The WiFi boiler thermostat can set the stop temperature of the circulating pump by pressing the “+” key or “-” key of the stop setting. The temperature displayed on the gauge outfit is the stop temperature of the circulating pump.


Ⅲ. Temperature setting of WiFi boiler thermostat


In general, the temperature of the ideal boiler thermostat to start is higher than the stop temperature, that is, start in high temperature and stop in low temperature. If the setting is reversed, the controller cannot work normally. The opposite is true for users who need a low-temperature start-up type, that is, the start temperature should be lower than the stop temperature.


Ⅳ. When it is necessary to force the circulating pump to start or stop the WiFi boiler thermostat, it need to press the manual key


When the manual key is pressed once, the start, stop indicator lights and actual temperature of the circulating pump start to flash, indicating that the controller has entered the manual working state; Press the manual key again, and the circulating pump will stop working; When the experiment is completed, the automatic key must be pressed. Only by pressing the automatic key can the WiFi boiler thermostat return to the automatic state and play the role of automatic temperature control.


Ⅴ. WiFi boiler thermostat connection


Insert the plug of the ideal boiler thermostat into the 220V power supply, and the circulating pump below 2000W is directly inserted into the socket of the controller. The circulating pump above 2kW needs to add an intermediate relay for conversion, and install the temperature probe on the water supply pipe of the boiler. If the user selects low-temperature startup, the temperature probe needs to be installed on the wet return of the boiler.